Permit: T07CM02931

Parcel: 140441130


Addresses:

6103 E FARMSTEAD DR

Inspection Status: Approved

Inspection History: ELECTRIC - UFER

Date Description Inspector Results Comments
08/17/2007 ELECTRIC - UFER Approved IVRS - Inspection :*
08/15/2007 ELECTRIC - UFER Denied IVRS - Inspection :
Install 2 ground rods 6 feet apart with a continuous grounding electrode connection
No ufer ground installed, you will have to install 2-8' ground rods, 6' apart for electric ground or install a ufer ground #4 copper wire clamped to 20 foot rebar with an approved bronz clamp and request as 02005 ufer inspection before you pour concrete. If you choose to install ground rod then you may pour concrete