Inspection History Details
Inspection Status: Approved
Inspection History: FIRE - FINAL
Permit Number - T07CM02911
Inspection Description - FIRE - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/08/2009 | FIRE - FINAL | Approved | ||
03/30/2009 | FIRE - FINAL | Cancelled | IVRS - RI canceled | |
03/30/2009 | FIRE - FINAL | Denied | 1. NEED SIDE-HINGED SWINGING DOOR(S) FOR EXIT REQUIRMENTS IFC/IBC 1008.1.2. OCCUPANT LOAD TABLE IFC/IBC 1004.1.2 SHOWS FACTOR OF 500 FOR WAREHOUSE 0R 300 FOR MERCANTILE -STORAGE, STOCK, SHIPPING AREAS. OCCUPANT LOAD CAN BE FROM 34 TO 56 STILL NEED SIDE-HINGED EGRESS DOORS. STILL WILL NEED TO HAVE TWO EGRESS DOORS IF TRING TO USE ONE EGRESS, TRAVEL DISTANCE IS OVER 75 FEET. NEED TO HAVE PLANS REVIEWED AGAIN AND HAVE CHANGES PUT ON PAGE G-1. |