Permit: T07CM02903

Parcel: 141096500

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/18/2008 FRAMING Approved IVRS - Inspection :*
03/13/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TIGHTEN ALL RED HEADS
2) BLOCK A/C BOOT LAUNDRY
3) CARRY LOAD FOR SOUTH SIDE GIRDER TRUSS THRU GARAGE TO STEM WALL
4) INSTALL VACUUM BREAKER ON HOSE BIB
5) POWDER ROOM TOILET REQUIRES MINIMUM 2 1/2" CLEANOUT
6) SUPPORT CONDENSATE DRAINS EVERY 8'
7) INSURE 1" CLEAR ROOF SHEATHING TO FURNACE B-VENT