Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM02903
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/25/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
02/22/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) SEE A ELEVATION FLOOR FRAMING CMSTC 16 X 72 REQUIRED EACH SIDE OF GARAGE (FROM LAST INSPECTION) 2) REAR SHEARWALLS TO TRUSS CONNECTION 2/D2 LTP 4S AT 16" ON CENTER |
|
02/20/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) VERIFY LVL=TO LSL FOR HEADERS 2) WRONG SIZE NAILS IN REAR PA'S AND SOUTH SIDE 3) UFER REBAR BENT OUT OF WALL SOUTH SIDE 4) E-STRAPS CMTC TYPE IS 3" WIDE, YOU HAVE A SMALLER STRAP INSTALLED ALSO AT HORIZONTAL STRAP AT GARAGE 5) TRUSS BRACING 10'-0" ON CENTER ON BOTTOM CHORD FROM BEARING AT DROP CEILING 6) 2/D2 TIE SHEARWALLS TO TRUSS BOTTOM CHORD PER THIS DETAIL LTPS TO CONNECT SHEAR TO TRUSS |