Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/17/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 11/05/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CORRECTIONS OK OK TO COVER WALLS RECALL FOR CLOSET FLANGES AFTER FF |
|
| 10/09/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* CONTRACTOR TO PAY REFEE FOR NON-COMPLIANCE WITH INSPECTION NOTES. |
|
| 10/05/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* PIPING NOT UNDER TEST AT KIT OR AT NEWLY INSTALLED TUB FLOOR WET YOU ARE WARNED THAT CONTINUED "DENIED" OR "N/R" INSPECTION RESULTS WILL RESULT IN REINSPECTION FEES |
|
| 09/27/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* TEST PIPING CHANGE AT KIT SECURE LAV STUB OUTS |
|
| 09/21/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - BACK UNIT GAS TEST GAUGE HAS DROPPED - TEST W/15 PSI GAUGE - UNIT 1 (FRONT) PSI TEST OK - CLEANOUT EXTENSIONS REQUIRE WYE PATTERN FITTINGS - OK TO COVER ALL OTHER AREAS, RECALL INSP FOR CORRECTIONS |
|
| 09/20/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) FILL TUBS FULL FOR INSPECTION 2) REPAIR LEAK ON ABS AT SINK IN EAST UNIT 3) INSTALL TUB AND PROVIDE TEST ON WEST UNIT 4) COMPLETE ALL WORK BEFORE CALLING FOR INSPECTION 5) COMPLETE LIST FROM 9/19/07 6) LIST MAY NOT BE COMPLETE 7) POST ADDRESS |
|
| 09/19/2007 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE TEST ON DWV 2) INSTALL CLEANOUTS ON KS'S 3) INSTALL 3/4" WATER TO BATHROOMS 4) SUPPORT GAS PIPING |
|
| 09/17/2007 | PLUMBING - INTERMEDIATE | Cancelled | CANCELLED PER CONTRACTOR JACOB #237-2802 | |
| 09/14/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |