Permit: T07CM02872

Parcel: 116300370

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T07CM02872

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/19/2008 BUILDING - FINAL Approved
12/15/2008 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST HOUSE NUMBERS
2) LABEL PLUMBING TYPE DEAD FRONT
3) ENERGY EFFICIENT STICKER
4) SECURE LIQUID TIGHT CONDENSOR DISCONNECTS
5) COMPLETE GRADING
6) CONDENSOR #2 OVER FUSED
7) SEAL LID GARGE A/C LINE
8) LIGHT FIXTURE IN BEDROOM CLOSET WITHIN 12" SHELVES
9) GFCI KITCHEN ISLAND COUNTER OVER 6"
10) NO POWER TO MASTER BATH GFCI
11) GAS CARD OK