Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T07CM02852
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/16/2008 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
05/14/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST HOUSE NUMBERS 2) COMPLETE LOW VOLTAGE LIGHTING ENTRY 3) LOWER CLEANOUTS TO GRADE 4) EXTEND TPR VALVE TANKLESS WATER HEATS TO EXTERIOR, COMPLETE DIRECT VENTING TO EXTERIOR SEAL MECH ROOM LID 5) VACUUM BREAKER HOSE BIB MECH ROOM 6) MISSING OUTLET COVER GFCI REAR PORCH 7) PROVIDE GAS BOND 8) SEAL WATER CLOSETS AT BASE 9) INSTALL FANS OR PLATE COVERS 10) MISSING LIGH FIXTURES POWDER ROOM 11) REMOVE OUTLETS BREAKFAST BAR COUNTER OVER 6" 12) PROVIDE SHUT OFF MASTER FIREPLACE 13) GFCI PROTECT LAUNDRY ? WITHIN 6' WATERS EDGE 14) EXPOSE JACUZZI TUBS GFCI |