Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM02849
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/14/2007 | FRAMING | Approved | IVRS - Inspection :* | |
09/12/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) WATER HEATER B-VENT REQUIRES MINIMUM 30 DEGREE PITCH |
|
09/05/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO WATER HEATER GAS VENT 2) REVERSE PITCH TUB DRAIN ABOVE KITCHEN 3) BX CABLE CANNOT CONNECT TO PLASTIC BOX KITCHEN 4) SECURE STAIR PONY WALL MUST HOLD 200 POUND LOAD 5) STAIR SHEARWALL CONNECTION IS NOT PER PLAN AT TRUSS 6) HALL BATH FLOOR NOT SCREWED DOWN TWO TRUSSES 7) NO PLAN/PERMIT |