Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM02823
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/08/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
01/10/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - DWV W/TEST THRU ROOF OK TO COVER - WATER PIPING W/TEST INSTALLED PER PLAN - MIN. REQUIREMENT FOR ENERGY EFFICIENCY IS 8' OF INSULATION TO AND FROM WH - POTABLE WATER OUTLETS W/HOSE ATTACHMENTS SHALL BE PROTECTED AGAINST BACKFLOW CONDITIONS WITH THE APPROPRIATE TYPE OF ASSEMBLY OR DEVICE PER UPC SEC 603.4.7 |
|
01/09/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
01/08/2008 | PLUMBING - INTERMEDIATE | Cancelled | CANCELLED PER GLENN | |
11/21/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* RP CERT RECEIVED FOR 009 AT FISH EQUIPMENT OK TO USE WATER |
|
11/16/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV AT FS1 AND SS1 W/TEST THRU ROOF OK RP NOT PER SPEC RP REQUIRES CERTIFICATION PRIOR TO USE |