Permit: T07CM02814

Parcel: 11105245C


Addresses:

3063 N ALVERNON WY


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T07CM02814

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
08/01/2007 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
SEWER OK
WATER PIPING COPPER TO PVC CONNECTION OK AT EXTERIOR
CONTRACTOR WILL PROVIDE BLUE TRACER WIRE PRIOR TO COVERING PVC
07/30/2007 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
- DRAIN PIPING INSIDE BUILDING OK TO COVER
- SEWER PIPING FROM 2-WAY CO TO CONNECTION W/EXISTING DENIED.
- REMOVE ROCKS, PROVIDE UNIFORM SLOPE AT MIN. 2% AND SUPPORT PIPING W/CLEAN COMPACTABLE DIRT
- PVC WATER PIPING MAY NOT ENTER BUILDING
07/27/2007 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
EACH FIXTURE REQUIRES A VENT
PLAN REQUIRES 3" CO ON SINK RISER
BUILDING SEWER REQUIRES CO
TRACER WIRE REQUIRED ON EXTERIOR PIPING