Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM02807
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/22/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/21/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) OVERSPAN FLOOR TRUSS AT STAIR 2) PLUMBING SOIL PIPING, CAN'T GO HORIZONTAL WITH VENT, ? SIX INCHES ABOVE FLOOD RIM OF FIXTURE IT SERVES 3) IN LAUNDRY, FIXTURES DRAINING INTO VENTS OF FIXTURES 1ST FLOOR WHY IS EVERY FIXTURE AT 2ND FLOOR REAR BATHROOM FLAT VENTED 4) BANG PLATE VTR 2ND FLOOR 5) BANG PLATE VTR ROMEX 2ND FRONT DOOR 6) BLOCK MECH 1ST FLOOR 7) OVER SPAN STUDS 2ND FLOOR |