Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM02807
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/02/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | ||
| 08/07/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HANGER (GIRDER) PLAN CALLS FOR LUS410=2210 POUNDS AHGUS INSTALLED ? (REAR) 2) (FRONT) HANGER FOR GIRDER NOT ON PLAN. NEED TRUSS DRAWINGS (FOR POUNDS) AT THAT POINT 3) MISSED NAILING GARAGE ROOF/2ND FLOOR ROOF (MARKED IN BLACK) 4) MISSED P-1 SHEAR AT PANTRY 5) MISSING HIP HANGER FRONT DOOR |