Date Description Inspector Results Comments
11/02/2007 EXT METAL CLIPS/EXT SHEATHING Approved
08/07/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HANGER (GIRDER) PLAN CALLS FOR LUS410=2210 POUNDS AHGUS INSTALLED ? (REAR)
2) (FRONT) HANGER FOR GIRDER NOT ON PLAN. NEED TRUSS DRAWINGS (FOR POUNDS) AT THAT POINT
3) MISSED NAILING GARAGE ROOF/2ND FLOOR ROOF (MARKED IN BLACK)
4) MISSED P-1 SHEAR AT PANTRY
5) MISSING HIP HANGER FRONT DOOR