Permit: T07CM02768

Parcel: 117070860


Addresses:

534 S HERBERT AV


Inspection Status: Approved

Inspection History: STUCCO MESH

Permit Number - T07CM02768

Inspection Description - STUCCO MESH

Inspection Status - Approved

Date Description Inspector Results Comments
02/20/2008 STUCCO MESH Approved
01/29/2008 STUCCO MESH Partial Approval IVRS - Inspection :*
1) NEED RECEPT 20 AMP AT KIT. COUNTER, 2 CIRCUITS REQUIRED
2) CONNECT LOOSE GROUND IN J-BOX
3) STUCCO AT OVER HANG TO BE REMOVED IS ASSORBING H20 FROM ROOF
4) PAINT AND SECURE CONDENSATE LINE NOT TO DRAIN ON NEIGHBORS PROPERTY
5) PLUMBING UNDER KIT SINK, NOT DONE CORRECTLY
6) PATCH ALL HOLES IN ROOF
7) STUCCO HAS CRACKS, SOME AREAS NEED REPAIR
8) MISSING SUB-FLOOR UNDER TILE
9) CAN LIGHT NOT SECURE BATHROOM
10) ALL WORK WAS COVER PRIOR TO INSPECTIONS, SPOT CHECKED ONLY
11) ALL NEW FLEX DUCT WORK IN ATTIC, ALL NEW SYSTEM LOOKS TO BE DONE IN A WORKMANSHIP MANNER
12) NEED TO RUN A. C. HEAT/COOL VERIFY ONLY ONE CIRCUIT NEEDED
13) 5' OF FLUE REQUIRED AT H20 HTR
01/16/2008 STUCCO MESH Not ready for Inspection IVRS - Inspection :*
1) MISSING PEE TRAP AT KITCHEN SINK, NEED CLEANOUT DISPOSAL LINE
2) NEED CLEANOUT AT WASHER
3) KITCHEN DRAIN VENT TO FAR FROM TRAP, CONCEAL 2" DRAIN
4) NEED GAS PRESSURE TEST IF OVER 6 MONTHS SINCE TURN OFF
5) COMB/RELIEF DUCTS H20 HTR
6) WHRE IS HEAT SOURCE
7) SERVICE ELECTRIC TWO GROUND RODS, H20 AND GAS BOND
8) ALL WIRING IS CONCEALED, COVERED
9) SMOKE DETECTORS IN BEDROOMS AND AT HALL WAY
10) CONSULT WITH R. MAJUTA CONCERNING ELECTRIC
11) HVAC ON ROOF, CONDENSATE, HEAT STRIP NOT MARKED, MISSING PEE TRAR
12) SEE SHEET OF EXISTING PROBLEMS SENT WITH PERMIT
13) ALL WORK COVERED TO BE CONTINUED TUES
14) AT OVERHANG, H20 GETTING BEHIND STUCCO
15) HAVE ELECTRICIAN POWER CHECK ALL CIRCUITS. CLEAN UP PANEL LOOSE GROUNDS, NUETRALS AND HOT WIRES
01/11/2008 STUCCO MESH Not ready for Inspection IVRS - Inspection :*
1) MISSING PEE TRAP AT KITCHEN SINK, NEED CLEANOUT DISPOSAL LINE
2) NEED CLEANOUT AT WASHER
3) KITCHEN DRAIN VENT TO FAR FROM TRAP, CONCEAL 2" DRAIN
4) NEED GAS PRESSURE TEST IF OVER 6 MONTHS SINCE TURN OFF
5) COMB/RELIEF DUCTS H20 HTR
6) WHRE IS HEAT SOURCE
7) SERVICE ELECTRIC TWO GROUND RODS, H20 AND GAS BOND
8) ALL WIRING IS CONCEALED, COVERED
9) SMOKE DETECTORS IN BEDROOMS AND AT HALL WAY
10) CONSULT WITH R. MAJUTA CONCERNING ELECTRIC
11) HVAC ON ROOF, CONDENSATE, HEAT STRIP NOT MARKED, MISSING PEE TRAR
12) SEE SHEET OF EXISTING PROBLEMS SENT WITH PERMIT
13) ALL WORK COVERED TO BE CONTINUED TUES