Inspection History Details
Inspection Status: Approved
Inspection History: STUCCO MESH
Permit Number - T07CM02768
Inspection Description - STUCCO MESH
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/20/2008 | STUCCO MESH | Approved | ||
01/29/2008 | STUCCO MESH | Partial Approval | IVRS - Inspection :* 1) NEED RECEPT 20 AMP AT KIT. COUNTER, 2 CIRCUITS REQUIRED 2) CONNECT LOOSE GROUND IN J-BOX 3) STUCCO AT OVER HANG TO BE REMOVED IS ASSORBING H20 FROM ROOF 4) PAINT AND SECURE CONDENSATE LINE NOT TO DRAIN ON NEIGHBORS PROPERTY 5) PLUMBING UNDER KIT SINK, NOT DONE CORRECTLY 6) PATCH ALL HOLES IN ROOF 7) STUCCO HAS CRACKS, SOME AREAS NEED REPAIR 8) MISSING SUB-FLOOR UNDER TILE 9) CAN LIGHT NOT SECURE BATHROOM 10) ALL WORK WAS COVER PRIOR TO INSPECTIONS, SPOT CHECKED ONLY 11) ALL NEW FLEX DUCT WORK IN ATTIC, ALL NEW SYSTEM LOOKS TO BE DONE IN A WORKMANSHIP MANNER 12) NEED TO RUN A. C. HEAT/COOL VERIFY ONLY ONE CIRCUIT NEEDED 13) 5' OF FLUE REQUIRED AT H20 HTR |
|
01/16/2008 | STUCCO MESH | Not ready for Inspection | IVRS - Inspection :* 1) MISSING PEE TRAP AT KITCHEN SINK, NEED CLEANOUT DISPOSAL LINE 2) NEED CLEANOUT AT WASHER 3) KITCHEN DRAIN VENT TO FAR FROM TRAP, CONCEAL 2" DRAIN 4) NEED GAS PRESSURE TEST IF OVER 6 MONTHS SINCE TURN OFF 5) COMB/RELIEF DUCTS H20 HTR 6) WHRE IS HEAT SOURCE 7) SERVICE ELECTRIC TWO GROUND RODS, H20 AND GAS BOND 8) ALL WIRING IS CONCEALED, COVERED 9) SMOKE DETECTORS IN BEDROOMS AND AT HALL WAY 10) CONSULT WITH R. MAJUTA CONCERNING ELECTRIC 11) HVAC ON ROOF, CONDENSATE, HEAT STRIP NOT MARKED, MISSING PEE TRAR 12) SEE SHEET OF EXISTING PROBLEMS SENT WITH PERMIT 13) ALL WORK COVERED TO BE CONTINUED TUES 14) AT OVERHANG, H20 GETTING BEHIND STUCCO 15) HAVE ELECTRICIAN POWER CHECK ALL CIRCUITS. CLEAN UP PANEL LOOSE GROUNDS, NUETRALS AND HOT WIRES |
|
01/11/2008 | STUCCO MESH | Not ready for Inspection | IVRS - Inspection :* 1) MISSING PEE TRAP AT KITCHEN SINK, NEED CLEANOUT DISPOSAL LINE 2) NEED CLEANOUT AT WASHER 3) KITCHEN DRAIN VENT TO FAR FROM TRAP, CONCEAL 2" DRAIN 4) NEED GAS PRESSURE TEST IF OVER 6 MONTHS SINCE TURN OFF 5) COMB/RELIEF DUCTS H20 HTR 6) WHRE IS HEAT SOURCE 7) SERVICE ELECTRIC TWO GROUND RODS, H20 AND GAS BOND 8) ALL WIRING IS CONCEALED, COVERED 9) SMOKE DETECTORS IN BEDROOMS AND AT HALL WAY 10) CONSULT WITH R. MAJUTA CONCERNING ELECTRIC 11) HVAC ON ROOF, CONDENSATE, HEAT STRIP NOT MARKED, MISSING PEE TRAR 12) SEE SHEET OF EXISTING PROBLEMS SENT WITH PERMIT 13) ALL WORK COVERED TO BE CONTINUED TUES |