Permit: T07CM02761

Parcel: 140552110

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/20/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/17/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO UFER
2) SHEARWALLS NOT NAILED PER PLAN-ALL SEAMS AND EDGES
08/15/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEAR NOT NAILED PER PLAN
2) HOLDOWN BOLTS/WASHERS NOT IN
3) GIRDER POSTS MISSING