Permit: T07CM02759

Parcel: 140552090

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/05/2007 FRAMING Approved IVRS - Inspection :*
08/31/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NOT READY PER HORACE
08/30/2007 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) DWV STACK REQUIRES CLEANOUT POWDER ROOM
2) KITCHEN SINK MUST VENT TO ROOF-SEE PLAN
3) NAIL 2ND FLOOR SILL PLATES AT 16" ON CENTER
4) HALL BATH DIRTY ARM EXCEEDS 42"
5) FIRESTOP REQUIRES 2 LAYERS 1/2" OSB
6) ANCHOR BOLT REQUIRED WITHIN 12" OF PLATE END STAIR
7) GIRDER TRUSS REQUIRES POST TO ?040
8) FIRE STOP FLOOR PENETRATIONS
9) STOPPED INSPECTION-TOO MANY ITEMS
08/23/2007 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1. ELECTRIC BOXES LATHED OVER
2. LATH NOT COMPLETE
3. OUTSIDE HOSE BIB REQUIRE ANTI-SIPHON VALVE
4. FIREBLOCK REQUIRES 2 LAYERS 1/2" OSB
5. NO PLANS ON SITE
6. 4 SWITCH ELECTRICAL BOX REQUIRES SUPPORT 2 ENDS
7. FIRE STOP 2ND FLOOR PENETRATIONS
8. 2ND FLOOR STACK REQUIRES CLEANOUT

STOPPED INSP. TO MANY ITEMS