Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM02709

Parcel: 141096440

Inspection Status: Approved

Inspection History: ROOF NAILING

Permit Number - T07CM02709

Inspection Description - ROOF NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
08/01/2007 ROOF NAILING Approved IVRS - Inspection :*
07/27/2007 ROOF NAILING Partial Approval IVRS - Inspection :*
1) MSTC28 NOT INSTALLED PER 10/D-5
2) PLUMBING WITHIN 1 1/4" OF PLATE EDGE MUST HAVE FHA STRAP
3) NORTH HOLDOWN NOT ON REAR SHEARWALL. PROVIDE ENGINEERS APPROVED REPAIR
4) PROVIDE PROOF THAT REAR PORCH COLUMN HAS ANCHOR BOLTS
5) ROOF OK TO DRY IN EXTERIOR CLIP NOT COMPLETE