Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM02708

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/17/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/16/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BRACED PANEL MISSING BETWEEN KITCHEN AND DINING ROOM NAIL SHEATHING TO DBL STUDS AT ALL HOLDOWNS
2) DIFFERENT PLAN ON SITE THIS TIME
08/15/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CHECK APPROVED PLANS FOR SHEAR PANEL LOCATION