Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T07CM02688

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
07/23/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
07/17/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. TRAP ARM MAY NOT CHANGE SIZE
2. TRAP AND TRAP ARM TO BE THE SAME SIZE
3. TRAP MAY BE ONLY ONE SIZE LARGER THAN TAILPIECE
LAV TAILPIECE IS 1 1/4"
4. A DRAIN MAY NOT CONNECT TO A VENT