Permit: T07CM02682

Parcel: 10408086C


Addresses:

800 W AUTO MALL DR


Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Permit Number - T07CM02682

Inspection Description - ELECTRIC - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
10/13/2008 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
10/08/2008 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
07/25/2008 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. SUPPORT WIRE TO BE ATTACHED BOTH ENDS - 300.11
2. SUPPORT OR REMOVE VDV CABLING -
725.3 & 24, 800.3 & 24, 300.11
3. SECURELY ATTACH FIXTURE TO GRID - 410.16
4. CONDUIT SUPPORTS TO BE EFFECTIVE
5. FILL UNUSED OPENINGS AND MISSING BOX COVERS

* DO NOT OCCUPY ANY AREAS WITHOUT PARTIAL FINALS FROM ALL TRADE INSPECTORS
07/21/2008 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. JUNCTION BOXES TO BE ACCESSIBLE
2. SUPPORT M/C WITHIN 12" OF CANS AND 6' INTERVALS HARD LIDS
3. CHECK BOX FILL

OK TO TILE FRONT SALE
OK HARD LID FRONT AFTER CORRECTIONS
06/24/2008 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. PROTECT PVC AT BASE PLATE

OK F & I ROOMS
OK 16 FLOOR BOXES & PVC CONDUIT

DO NOT ONE SIDE
06/17/2008 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. DO NOT CALL BEFORE ELECTRICIAN TELLS YOU HE IS COMPLETE
2. DRYWALL NOT TO BE INSTALLED BEFORE APPROVAL
04/18/2008 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
03/03/2008 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
WALLS 11, 12, 13

CONTRACTOR WILL INSTALL & COVER UNDERGROUND
TO COLLISION REPAIR AS IT IS HIGH TRAFFIC AREA WILL LEAVE 3 POINTS OF INSPECTION
02/14/2008 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK WALL COVER - GSM, KEY TRACK, BDC, SOUTH BREAKROOM
ALSO, BDC UNDERGROUND 2 SETS DATA, FLOOR RECEPTACLES