Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM02672
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/25/2008 | FRAMING | Approved | IVRS - Inspection :* 1) SEE ATTACHED ENGINEERING TRUSS REPAIR |
|
01/24/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED ROB'S APPROVAL ON ENGINEERED LETTER |
|
01/07/2008 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
12/28/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
12/06/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RAFTER THAT IS CUT NEEDS ENGINEERING APPROVAL |
|
12/04/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAILS NOT CHANGED OUT |
|
12/03/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) WRONG NAILS IN PROBLEM HANGER |
|
11/28/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 16D SINKDERS USED WHERE 16D COMMONS ARE NEEDED IN BEAM AND HANGER |
|
11/07/2007 | FRAMING | Partial Approval | IVRS - Inspection :* OK TO INSULATE 1. HAVE ROOF TRUSS LAYOUT WITH HANGER SIZE & LOCATION SIGNED & STAMP |
|
11/01/2007 | FRAMING | Denied | 1) ENGINEERED FIX REQUIRED CUT TRUSS AT GIRDER BEAM CONNECTION 2) OVERFRAME STUDS S.E. CORNER MASTER CLOSET 3) 8-16D REQUIRED OVERKNOTCH DBL TOP PLATES REPAIR KITCHEN EAST WALL EACH SIDE OF FHA STRAP |
|
10/25/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OVERSPAN STUD 2ND FLOOR TOTAL 2 2) NEED H20 IN ALL SOIL PIPES 3) REMOVE WASHER DRAIN FROM BATHROOM GROUP 2ND FLOOR 4) CHANGE OUT HANGER AT ROOF GIRDER TO BEAM |