Permit: T07CM02672

Parcel: 141340180

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM02672

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/25/2008 FRAMING Approved IVRS - Inspection :*
1) SEE ATTACHED ENGINEERING TRUSS REPAIR
01/24/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED ROB'S APPROVAL ON ENGINEERED LETTER
01/07/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
12/28/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
12/06/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RAFTER THAT IS CUT NEEDS ENGINEERING APPROVAL
12/04/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAILS NOT CHANGED OUT
12/03/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) WRONG NAILS IN PROBLEM HANGER
11/28/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 16D SINKDERS USED WHERE 16D COMMONS ARE NEEDED IN BEAM AND HANGER
11/07/2007 FRAMING Partial Approval IVRS - Inspection :*
OK TO INSULATE

1. HAVE ROOF TRUSS LAYOUT WITH HANGER SIZE & LOCATION SIGNED & STAMP
11/01/2007 FRAMING Denied 1) ENGINEERED FIX REQUIRED CUT TRUSS AT GIRDER BEAM CONNECTION
2) OVERFRAME STUDS S.E. CORNER MASTER CLOSET
3) 8-16D REQUIRED OVERKNOTCH DBL TOP PLATES REPAIR KITCHEN EAST WALL EACH SIDE OF FHA STRAP
10/25/2007 FRAMING Partial Approval IVRS - Inspection :*
1) OVERSPAN STUD 2ND FLOOR TOTAL 2
2) NEED H20 IN ALL SOIL PIPES
3) REMOVE WASHER DRAIN FROM BATHROOM GROUP 2ND FLOOR
4) CHANGE OUT HANGER AT ROOF GIRDER TO BEAM