Permit: T07CM02654

Parcel: 108253970


Addresses:

2028 E RIVER RD 10

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
06/08/2009 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
06/05/2009 PLUMBING - INTERMEDIATE Partial Approval CLOSET FLANGES UPSTAIRS OK. OK TO SET TOILETS
UNIT 100 & 105 DUTCHMAN FOR CLOSET FLANGE OK ALSO.
05/21/2009 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) CORRECT 100 & 105 316.3.2 FIRST FLOOR EXCEPT 100 & 105 OK TO SET TOILETS
02/18/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
02/17/2009 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
04/17/2008 PLUMBING - INTERMEDIATE Partial Approval 1. CORRECTIONS MADE OK
OK TO COVER ALL AREAS
2. YARDWATER OK TO COVER
04/15/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
SUPPORT THE TRAP ARMS
TRAP ARM MAY NOT CHANGE SIZE
TRAP ARM OVER 90 DEG. REQUIRES CLEANOUT
MAY NOT DUMP A DRAIN INTO A VENT
PLUMBERS TAPE NOT AN APPROVED STRAP
ABS "SHIMS" NOT APPROVED SUPPORT
03/19/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OK FOR PRE-ROCK FIRST FLOOR OVERHEAD ONLY

AS A COURTESY:
a. SUPPORT TRAP ARMS
b. SUPPORT VERTICAL PIPE
c. NO BACK-PITCHED SECTIONS
d. SUPPORT OVERHEAD
e. TUBS TO BE FILLED