Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM02579
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/19/2007 | FRAMING | Approved | IVRS - Inspection :* | |
10/18/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY-CANCELLED PER SUPERVISOR |
|
10/17/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL OFF FLOOR TRUSS HANGER AT BEAM CENTER OF GARAGE 2) DRAFT STOP 2ND FLOOR TUBS AT P-TRAPS 3) FILL ALL NAIL HOLES IN FHA STRAP WITH 16D NAILS 4) ENGINEER FIX FOR TRUSSES NOT SEATED IN HANGERS ABOVE KITCHEN 5) SEAL PAPER LEFT ON KITCHEN HOOD DUCT WORK 6) GROUND FOR LOW VOLTAGE TO PANEL 7) PROTECT WIRES FROM METAL GUSSETS IN FLOOR TRUSSES AT GARAGE 8) NAIL PROTECT WIRES TOP PLATE KITCHEN SHEARWALL 9) UNABLE TO OPEN PANEL 10) GAUGE FOR SOLAR LINE STUCK AT 34 POUNDS 11) NAIL PROTECT REFRIDGE WATER LINE TO PLATE SHEARWALL 12) STOPPED INSPECTION AT MAIN FLOOR-NOT READY |
|
10/04/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED |