Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/16/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 10/15/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ADD FOR PROPER TRIMMERS ABOVE WATER HEATER OPENING 2) SUPPORT WATER HEATER STAND BACK SIDE 3) STRAP GLUE LAM NORTH END 4) NAIL OFF JOIST HANGERS ON SIDES OF FLOOR TRUSSES IN GARAGE 5) DRAFT STOP ARCH FROM GARAGE TO FRONT DOOR 6) EPOXY HOLDOWN NEEDED BY FRONT DOOR WITH INSPECTION 7) SUPPORT 2" DWV MAX 4' IN GARAGE CEILING 8) SUPPORT MAIN POTABLE WATER LINE AT GARAGE WALL 9) VACUUM BREAKER NEEDED AT HOSE BIB 10) SUPPORT 2" DWV ABOVE FRONT ENTRY 11) STOPPED INSPECTION-NOT READY GARAGE AND FOYER ONLY |