Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM02575
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/27/2007 | FRAMING | Approved | IVRS - Inspection :* | |
09/26/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FILL DWV 2) BANG PLATE SOLAR LINES ABOVE TUB 2ND FLOOR |
|
09/24/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) (5) 2 X 4'S NEEDED NORTH END OF BEAM IN KITCHEN 2) BLOCKING AND NAILS REQUIRED AT ALL 524 DETAIL 1ST & 2ND FLOOR 3) DRAFT STOP CEILING EAST OF GARAGE SERVICE DOOR COLUMN 4) TIGHTEN RED HEADS 5) FINISH STUCCO 6) HTC4 CLIP NEEDED PER 516 7) (4) 2 X 4 POST NEEDED UNDER FLUSH HEADER IN FOYER 8) SUPPORT ABS ABOVE FRONT DOOR MAX 4' 9) TPR FOR WATER HEATER BACK PITCHED 10) STOPPED INSPECTION |