Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM02574
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/04/2007 | FRAMING | Approved | IVRS - Inspection :* | |
10/03/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FILL ALL NAIL HOLE IN FHA PLATES OVER A COIL LINE NORTH WALL MAIN FLOOR 2) MINIMUM 3/4" OSB AT FIRESTOP OF DUCT CHASE AT CEILING 2ND FLOOR 3) NO METER |
|
10/01/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PREVIOUS INSPECTION NOT COMPLETED |
|
09/28/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SUPPORT WATER HEATER PLATFORM 2) TIGHTEN ANCHOR BOLT WES OF ELECTRICAL PANEL IN GARAGE 3) NAIL DOWN FLOOR TRUSS SHEAR MAX 6" ON CENTER ABOVE REFRIDGERATOR 4) DRAFTSTOP AROUND 3" ABS IN FOYER 5) STAPLE MESH AT PEAK OF GARAGE GABLE 6) 12" MIN CLEARANCE ABOVE RECESSED LIGHT TO PEX IN FOYER 2 SPOTS 7) NAIL PLATE HOT WATER LINE IN LAUNDRY ROOM 8) SOLAR LINES FOR WATER HEATER INSTALLED AND TESTED 9) SUPPORT ABS 3" IN GARAGE CEILING 10) STOPPED INSPECTION-NOT READY |