Permit: T07CM02570

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/11/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
10/10/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspectio
- NAIL IN 3" ABS MAIN FLOOR FRONT BATHROOM
- MINIMUM 12" CLEARANCE FOR PEX FROM RECESSED LIGHT IN KITCHEN
- REANCHOR CONDENSATE LINE MAIN FLOOR SOUTH WALL
- STAPLE WIRE WITHIN 10" FOR RECEPTACLE UNDER SMART PANEL
- BANG PLATE PROTECTION WIRES AT TOP PLATES IN GARAGE
- SUPPORT SHOWER PLUMBING

STOPPED INSPECTION REFEE
10/09/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
FINISH PREVIOUS INSPECTION
10/08/2007 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*