Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/07/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/06/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEAR NEEDED 12' FROM BACK GARAGE WALL TO FRONT 2) H2.5'S NEEDED ON LVL IN RAFTERS 2ND FLOOR 3) CMST NEEDED STAIRWAY SHEAR WEST AND NORTH WALL |