Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM02561
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/05/2007 | FRAMING | Approved | IVRS - Inspection :* | |
10/04/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIX TRUSS PER PREVIOUS INSPECTION 2) NUT NEEDED ON RISER CLAMP |
|
10/03/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RAFTER FIX NEEDED PER PREVIOUS INSPECTION |
|
10/02/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MINIMUM 3/4" OSB FOR FIRESTOP AT DUCT IN RAFTERS FOR FIRESTOP 2) DRAFTSTOP FLOOR OF DUCT CHASE 3) TRUSS FIX FOR RAFTERS AT GIRDER |
|
10/01/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TRUSS FIX FOR RAFTER 2) FIRESTOP MAIN DUCT CHASE AT FLOOR AND CEILING 3) HTC4 NEEDED 2 X 6 INTERIOR KITCHEN WALL 4) PROPER NAILING ON FHA STRAP UPSTAIRS |
|
09/28/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FOUNDATION ANCHORS NORTH WALL GARAGE MAX 32" ON CENTER 2) CRIPPLES NEEDED UNDER WATER HEATER STAND FOR PROPER SUPPORT 3) 2-2 X 4 POST FROM ABOVE IN FLOOR TRUSSES ABOVE KITCHEN SINK 4) HTC4 CLIP NEEDED WEST LAUNDRY WALL TOP PLATE 5) SEAL PAPER AROUND BOXES SOUTH WALL GARAGE 6) NAIL PROTECTION TOP PLATE SOUTH WALL GARAGE 7) FILL ALL NAIL HOLES IN FHA STRAPS 8) AIR TEST ON SOLAR FOR WATER HEATER 9) NAIL PROTECT 1 1/2" ABS TOP PLATE ABOVE WATER HEATER 10) NO PITCH ON 3" ABS ABOVE KITCHEN 11) STOPPED INSPECTION-NOT READY |