Permit: T07CM02560

Parcel: 141350690

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM02560

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/27/2007 FRAMING Approved IVRS - Inspection :*
09/26/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL DOWN 2ND FLOOR SHEARWALL SOLE PLATES
2) FILL NAIL HOLES IN FHA STRAP PER PREVIOUS INSPECTION
3) FINISH STUCCO NORTH SIDE
4) DRYER OUTLET BOX NOT NAILED TO STUD
5) MINIMUM 30" CLEARANCE ABOVE ATTIC ACCESS
09/24/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL DOWN SOLE PLATES OF INTERIOR AND EXTERIOR SHEAR WALLS PER PLAN
2) HTC4 CLIPS NEED PER 515/516 ON INTERIOR WALLS
3) (4) 2 X 4 POST IN CENTER WALL BEHIND DISHWASHER
4) ATTACH GIRDER TRUSS RAFTER TO STAIRWELL WALL WITH (5) LTP4'S
5) FILL ALL HOLES IN FHA STRAPS AT TOP PLATES
6) SHOWER PAN NEEDS TO BE INSTALLED 2ND FLOOR
7) FILL UP SOLAR WATER HEATER TEST
8) NAIL THROUGH CONDENSATE LINE TOP PLATE IN GARAGE
9) DRAIN SECONDARY CONDENSATE LINE IN OBVIOUS LOCATION
10) STOPPED INSPECTION
09/06/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL OFF FRONT GARAGE WALL PER SHEAR
2) NAIL OFF TOP OF SHEAR PANEL NORTH OF ENTRY