Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM02557
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/07/2007 | FRAMING | Approved | IVRS - Inspection :* | |
11/06/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK REGISTER ABOVE FRONT DOOR 2) BLOCKING NEEDED IN FLOOR TRUSSES PER PLAN BETWEEN KITCHEN AND LIVING ROOM 3) 2-2 X 4 POST AND BLOCK SOUTH GARAGE WALL 4) RAFTER FIX FOR GIRDER TRUSS NOTCHED FOR 2" ABS ABOVE BATHROOM 2 X 6 WALL 5) HOLE IN TAR PAPER BELOW WINDOW UPSTAIRS SOUTH BEDROOM 6) FAN BOX NEEDED IN MASTER BATH 7) A/C FAN TO ATTIC STAPLES TO INSIDE WALL BEHIND MASTER TOILET |
|
11/05/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2-2 X 4 POSTS FROM ABOVE 2 X 10 HEADER 2) 2 X 4 X 2 X 6 POSTS NEEDED MAIN FLOOR NORTH WALL 3) SUPPORT WATER HEATER PLATFORM 4) DRAFT STOP UNDER TUBS 5) BLOCK SEAM IN OSB AT 303 & 508 DETAIL 6) BLOCK REGISTERS 2ND FLOOR 7) 2-2 X 6 HEADER NEEDED ABOVE MASTER SHOWER SURROUND 8) FINISH ELECTRIC 9) SUPPORT 2" VENT 2ND FLOOR MASTER BATH 10) NOT READY-STOPPED INSPECTION |
|
11/02/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER SUPER |
|
11/01/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OVERNOTCHED STUD NORTH WALL GARAGE FOR ABS 3" 2) SUPPORT WATER HEATER STAND 3) FINISH ELECTRIC IN OVERHEAD GARAGE WALL 4) FINISH ELECTRICAL 5) FINISH DUCT WORK |