Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM02550
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/28/2009 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
07/06/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) LOW PRESSURE AIR TEST TODAY BETWEEN MH #4 & MH #5, ALSO BETWEEN INTERCEPTOR AND MH #5 (MANHOLE #5 AND CLEANOUT ?) |
|
06/16/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
06/15/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. PVC ROOF DRAIN AND OVERFLOW DRAIN AT NORTHWEST CORNER OF BLDG. OK 2. EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN SIX INCHES ABOVE THE FIXTURE BEING SERVED BEFORE OFFSETTING HORIZONTALLY 3. VENTS SHALL BE INSTALLED LEVEL OR SO DESIGNED AS TO DRAIN BACK TO THE FIXTURE BEING SERVED 4. STAND-PIPE RECEPTOR TO BE A MINIMUM OF EIGHTEEN INCHES IN LENGTH. |
|
06/11/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* ABS AND WATER PIPING AT NORTHWEST CORNER -- OK TO COVER |
|
06/05/2009 | PLUMBING - INTERMEDIATE | Partial Approval | OK TO COVER WALLS AT PHARMACY AND EMPLOYEE'S RESTROOM INCLUDING MOP SINK | |
06/04/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK FOR CONCRETE AT BAKERY/DELI |
|
06/03/2009 | PLUMBING - INTERMEDIATE | Partial Approval | NORTHWEST PLUMBING WALL IN GROCERY -- OK TO COVER | |
06/02/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. SUPPORT HORIZONTAL PIPING IN THE WALL PIPING MAY BE SUPPORTED TO THE METAL STUD, BUT NOT BY THE METAL STUD - ISOLATE ABS FROM METAL STUD 2. REMOVE RECTOR SEAL AT CLEANOUT 3. ADD HANGERS AS REQUIRED |
|
02/06/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* GREASE WASTE AT PRODUCE AREA SANITARY SEWER AT PRODUCE TO OUTSIDE BLDG. OK WATER TEST ONE RISER TO TEN FEET |