Permit: T07CM02550

Parcel: 10512024D


Addresses:

4040 N ORACLE RD

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
03/30/2009 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
03/26/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
BACK ROOM ROUGH SOIL PIPING W/TEST OK
RECALL FOR PRE-SLAB INSP.
03/19/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
03/17/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
03/16/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
03/16/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
NOTHING READY
RE-WORK IN GROCERY REQUIRE REINSPECTION AND TEST
03/14/2009 PLUMBING - ROUGH, SOIL Partial Approval PAID AFTER HRS. INSP. REQUESTED BY MARK W/AP SW
PAID W/CHECK 3438 (JAMES HALL)

GROCERY UNDER FLOOR P-410 CWV OK TO COVER
GROCERY P-400 PARTIAL; SEE INITIALS
CWV AND GW OK
FOOD SERVICE P311 SANITARY AND GW OK
PHARMACY P321 OK

FIXTURE OUTLET AND VERTICAL WASTE (TAILPIECE)
SHALL BE TWO PIPE SIZES SMALLER THAN P-TRAP
SEE UPC 910.4 AND ILLUSTRATED FIGS. 9-26 & 9-28

INSTALL 2X3 INCREASER AT P-TRAP, TEST WYES ON VENTS AND RETEST AT PRE-SLAB OR FS INSTALL.

REDLINE ADDITION AT RELIEF VENT
03/13/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
2PM INSP. REQUESTED AND PROVIDED -- NOT READY
03/12/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
03/11/2009 PLUMBING - ROUGH, SOIL Partial Approval - 4" CWV FOR FROZEN FOODS OFF OF COLUMNS 10-13 AS INITIALED ON P-400
- 4" CWV FOR PRODUCE CASES OFF OF COLUMN 10 BETWEEN
C AND D AS INITIALED ON P-400 OK TO COVER
- WATER TEST ONE RISER TO TEN FEET
- INSPECTED AFTER HOURS BETWEEN 4:30 AND 8:30 TO BE PAID FROM ADOLPHSON AND PETERSON ACCOUNT - 2 HRS.
02/27/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
02/26/2009 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
MARK 602-908-2472

SEAL PIPING FROM COL. 5 THRU COL. 8 ALONG B LINE OK
RECALL FOR MISSING FIXTURES.
NOTE: WORK ON SHADING AND ROCKS
02/02/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection NO WORK ON BLDG. TODAY