Permit: T07CM02550

Parcel: 10512024D


Addresses:

4040 N ORACLE RD


Inspection Status: Approved

Inspection History: ELECTRIC - OUTDOOR LIGHTING

Permit Number - T07CM02550

Inspection Description - ELECTRIC - OUTDOOR LIGHTING

Inspection Status - Approved

Date Description Inspector Results Comments
09/11/2009 ELECTRIC - OUTDOOR LIGHTING Approved IVRS - Inspection :*
04/17/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
OK 2 LT. POLE BASES OR REMAINDER OF POLE BASES
CALL TO INSPECT MAKE UP IN WIRING
04/15/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
SEE PLANS AS MARKED FOR U.G.
03/31/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
03/30/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
03/25/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
03/24/2009 ELECTRIC - OUTDOOR LIGHTING Not ready for Inspection IVRS - Inspection :*
03/24/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
03/23/2009 ELECTRIC - OUTDOOR LIGHTING Not ready for Inspection IVRS - Inspection :*
03/23/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
03/20/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
03/16/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
03/13/2009 ELECTRIC - OUTDOOR LIGHTING Not ready for Inspection IVRS - Inspection :*
03/13/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
03/12/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
03/06/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
OK POLE TO POLE AND POLE BASES AS MARKED
03/05/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
1. AT BASKIN ROBBINS GROUNDING TO BE AS PER 250.64 (E)

*WILL SCHEDULE BEFORE HRS. INSPECTION FOR CROSS OVER
03/04/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
1. LOCKED @ BASKIN ROBBINS BUILDING EXISTING ROMEX DOES NOT NEED TO BE REMOVED UNLESS TI's ARE TO BE RENOVATED. WALKED WITH JIM OF AP
03/03/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
02/27/2009 ELECTRIC - OUTDOOR LIGHTING Not ready for Inspection IVRS - Inspection :*
NO INSPECTION NEEDED
02/25/2009 ELECTRIC - OUTDOOR LIGHTING Not ready for Inspection IVRS - Inspection :*
SITE PROGRESS INSPECTION TONY FROM CASCADE
WILL BE READY FOR U.G INSPECTION ON 2/26
02/20/2009 ELECTRIC - OUTDOOR LIGHTING Not ready for Inspection IVRS - Inspection :*
02/19/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
02/18/2009 ELECTRIC - OUTDOOR LIGHTING Not ready for Inspection IVRS - Inspection :*
02/17/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
TEMP OUTDOOR LIGHTING TO MEET OUTDOOR LIGHTING CODES - PLEASE SUBMIT FOR REVIEW

1. LABEL DISCONNECTS FOR TEMP LIGHTING
2. PLEASE PROVIDE ROOF ACCESS
02/09/2009 ELECTRIC - OUTDOOR LIGHTING Not ready for Inspection IVRS - Inspection :*
02/06/2009 ELECTRIC - OUTDOOR LIGHTING Not ready for Inspection IVRS - Inspection :*
02/05/2009 ELECTRIC - OUTDOOR LIGHTING Not ready for Inspection IVRS - Inspection :*
02/04/2009 ELECTRIC - OUTDOOR LIGHTING Not ready for Inspection IVRS - Inspection :*
02/03/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*
01/29/2009 ELECTRIC - OUTDOOR LIGHTING Partial Approval IVRS - Inspection :*