Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM02547
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/19/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
02/27/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* - WATER TEST DWV & WATER PIPING NEW SINK IN LOBBY AREA OK - CONDENSATE DRAIN CANNOT TERMINATE INTO A VENT SINK - PROVIDE CORRECT TERMINATION OF CONDENSATE DRAIN |
|
02/26/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST OVERFLOW DRAINS & RAIN DRAINS OK PROVIDE CORRECT SUPPORTS FOR OVERHEAD RAIN DRAIN AND OVERFLOW RAINDRAINS WATER PIPING IN RESTROOM OK CLOSET FLANGES OK |
|
02/22/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* RE-ROUTE OF STOOL DRAIN OK IN MENS RESTROOM ONLY 1. RAIN DRAINS REQUIRE CORRECT SUPPORTS AT CORRECT INTERVALS WITH TEST IN PLACE 2. IN WALL PIPING TO BE RE-WORKED IN RESTROOM |
|
02/14/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 2 - SOUTH RD & OFRD WATER TEST OK 3-COMP SINK INSTALL OK AFTER DAP |
|
02/12/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST ADDITION OF HAND SINK AND REPAIRS TO 3-COMP SINK AREA OK NOTE: YOUR BUILDING ROOF PATTERN HAS CHANGED AND YOU ARE REQUIRED BY CODE TO HAVE OVERFLOW DRAINS OR SCUPPERS INSTALLED PROPERLY TO AVOID A ROOF FAILURE. |