Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07CM02544
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/18/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* RECEIVED (5) IN HOUSE BACKFLOW CERTIFICATIONS |
|
01/10/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* COMPLETE ITEM #1, #3, #4 AS PER 1/7/08 INSPECTION OR YOU WILL BE CHARGED A REFEE |
|
01/07/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. COMPLETE ALL INTERMEDIATE WORK PER PLAN, PROVIDE ALL TESTING, AND ACCESS TO ALL PIPING FOR INSPECTION 2. ALL INDIRECT DRAINAGES TO HAVE 1" AIR GAP AT TERMINATION 3. PROVIDE FULL SIZE RIDGID PIPING FOR ESPRESSO DRAIN WITH MINIMUM FALL 4. PROVIDE BACKFLOW CERTIFICATIONS 5. PROVIDE CORRECT FAUCET OR BACKFLOW PROTECTION FOR HAND HELD TRIGGER SPRAYER AT 3-COMP SINK 6. CALL IN ALL PLUMBING INSPECTIONS ON YOUR PERMIT CARD FOR FINAL INSPECTION 7. S/C SINK REQUIRES VACUUM BREAKER ON HOSE THREAD END |