Permit: T07CM02538

Parcel: 141314650

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM02538

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/02/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/01/2007 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) ITEMS BELOW NOT FIXED
2) UNCOVER SOIL PIPE REPAIR FOR INTERMEDIATE INSPECTION
07/27/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ITEMS 2, 3, 4, 5, 7, 9 & 10 FROM 7/23/07 INSPECTION NOT DONE
07/23/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING HIP HANGERS REAR PORCH
2) REAR PORCH ROOF OSB TURNED WRONG WAY BLKS AT 24" ON CENTER
3) DBL 2 X 4 REAR PORCH SIDE BEAM SPLICE, MUST BE FULL MEMBER
4) 1ST/2ND FLOOR STRAPS AT 2ND FLOOR ABOVE GARAGE GLU LAM
5) WILL NEED FLOOR REPAIR DETAIL 1ST FLOOR SHOWER TO VENT
6) 7/SD4 TIE SHEARWALL TOP TO 2ND FLOOR, SPEC PAGE SEE #D STRAPS CS20 AT 32" ON CENTER
7) BLK BELOW PLATES 2ND FRONT POP OUTS BEARING ON 1/2 OSB
8) EAST SIDE FRIEZE BOARDS NOT NAILED
9) GUSSET PLATE MISSING FRONT 2ND FLOOR ROOF GABLE
10) 6 TRUSSES IN FROM REAR ROOF SOUTH, 1ST FULL ROW OSB FROM TOP OF RIDGE JOINT NOT NAILED, MARKED ON FLOOR