| 07/16/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 07/11/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE SEDIMENT TRAPS ON WATER HEATER AND GAS PACK ON ROOF 2. PROVIDE ROOF JACK FOR GAS PIPING THROUGH ROOF 3. PROVIDE PERMIT AND DRAWING THAT ARE APPROVED FOR REPIPING GAS 4. PROVIDE PETITION OF APPEAL FOR T&P AT WATER HEATER 5. GAS PIPING IN DRIVEWAY MIN. 6" ABOVE GRADE 6. PROVIDE NEW PSI TEST |
|
| 06/28/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. TEST NOT HOLDING 2. COMPLETE LIST FROM 6/22/07 |
|
| 06/22/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE AGA APPROVED VALVE OUTSIDE AT METER OR REMOVE 2. ADD APPROVED SUPPORT FOR GAS PIPING OUTSIDE 3. PROVIDE SUPPORT FOR GAS PIPING ON ROOF 4. PROVIDE LADDER TO GET ON ROOF 5. PROVIDE AGA APPROVED VALVE FOR FURNACE/HEATER 6. LIST MAY NOT BE COMPLETE 7. TEST NOT HOLDING |