Permit: T07CM02486

Parcel: 118121420


Addresses:

333 E 24TH ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/14/2007 FRAMING Approved IVRS - Inspection :*
08/10/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEAL SOLE PLATE AT STUCCO WEEP
2) COMPLETE INTERIOR HOLDOWNS PER REVISION WITH EPOXY
3) NEED CITY APPROVED TRUSS DRAWINGS ON SITE FOR REVIEW
4) NEED BLDG OFFICIAL OK TO GO OVERHEAD WITH ELECTRICAL MAIN
5) ADD BANG PLATES AT PIPING OR MAINTAIN 1 1/2" FROM STUD FACE
6) PROVIDE A COMPLETE WATER TEST ON ALL DWV
07/26/2007 FRAMING Not ready for Inspection IVRS - Inspection :*