Inspection History Details
Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
Permit Number - T07CM02459
Inspection Description - SHEET ROCK NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/02/2007 | SHEET ROCK NAILING | Approved | IVRS - Inspection :* | |
11/01/2007 | SHEET ROCK NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CHECK GARAGE LID NAILING 6" ON CENTER THROUGHOUT 2) KITCHEN SHEARWALL CALLS FOR 4" ON CENTER NAILING 3) LOOSE SHEETS STAIRWELL 4) ALL UPSTAIRS BRACED PANELS REQUIRE 4" ON CENTER NAILING |
|
10/31/2007 | SHEET ROCK NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CEILING GYPSUM IN GARAGE NAIL OFF 6" ON CENTER WITH 1 7/8" NAILS 2) SHEAR IN KITCHEN NEEDS NAILS NOT SCREWS 3) NAILS NOT SCREWS UPSTAIRS SHEAR PER PLAN 4) 3 CLIPS PER MANUFACTURERS SPECS INSIDE CORNER MASTER CLOSET |