Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM02456
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/09/2007 | FRAMING | Approved | IVRS - Inspection :* | |
10/08/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE SPECIAL INSPECTION REPORT FOR ANCHOR BOLTS FOR "P" HOLDOWNS-REQUIRES EPOXY. APPEARS TO BE WEDGE ALL 2) HANGER MISSING ON MH6 TRUSS BY 6050 3) TRUSS SHEAR BLOCKING PANELS REQUIRE ENDS AND EDGES NAILED AT 3" ON CENTER 4) NO SECOND FLOOR DWV TEST 5) NAIL SHEAR BLOCK PANELS TO PLATES AND FLOORS |