Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM02454

Parcel: 141352340

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM02454

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/03/2007 FRAMING Approved IVRS - Inspection :*
10/02/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL DOWN FLOOR TRUSS SHEAR PANELS FROM ABOVE PER 303/508
2) DRAFT STOP UNDER TUB IN GARAGE
3) COIL STRAP KITCHEN HEADER
4) NAIL OFF HANGER FOR STAIRWAY HEADER ABOVE BATHROOM
5) 2 X 10 HEADER NEEDED 2ND FLOOR SOUTH WEST BEDROOM
6) HEALS OF RAFTERS AWAY FROM GIRDER UPSTAIRS NORTH BEDROOM
7) WIRE PINCHED BETWEEN STUD AND TAR PAPER EAST WALL GARAGE
8) HANG RECESSED CAN AT BOTTOM OF STAIRS