Permit: T07CM02418

Parcel: 141313150

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM02418

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/21/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/17/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL SHEAR PANELS TO ROOF ABOVE POWDER ROOM
2) NAIL BLOCKS TO ROOF TRUSS TO TRUS LIVING ROOM TO 2ND FLOOR INTERIOR WALL
3) NEED NAILING FOR SHEETROCK G-1 LIVING ROOM TO SHEAR BLOCK PANELS BETWEEN TRUSSES
4) SOME TRUSSES IN LIVING ROOM ROOF OUT OF PLUMB 1/4" PER FT MAX
5) TWO TRI-ANGLE SHAPE OSB ON ROOF TURNED WRONG WAY BLOCK JOINT
6) 5'-0" CS20 STRAP FRONT/BACK OF LIVING ROOM AT TRUSS TO TRUSS JOINT