Permit: T07CM02362

Parcel: 141340150

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM02362

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
01/25/2008 FRAMING Approved IVRS - Inspection :*
1) SEE ATTACHMENT ON ENGINEERED TRUSS REPAIR
01/24/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED ROB'S APPROVAL ON ENGINEERED LETTER
01/07/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
12/28/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
12/06/2007 FRAMING Partial Approval IVRS - Inspection :*
1) NEED TRUSS REPAIR AT CUT TRUSS
12/04/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAILS NOT CHANGED OUT
12/03/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) WRONG NAILS IN (PROBLEM HANGER)
11/28/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NOTE: HTU26-2 INSTALLED WITH .148 SINKERS AND NAIL 3 1/2" LONG HANGER CALLS FOR 16 .162 = .64 PERCENT REDUCTION IN LOAD CAPACITY. TO RENAIL USE COMMON 16D 3 1/2" LONG
11/27/2007 FRAMING Partial Approval IVRS - Inspection :*
1) HANGER PROBLEM NOT RESOLVED-OK WAS GIVEN TO INSULATE NOT SHEETROCK
11/23/2007 FRAMING Cancelled IVRS - RI canceled
11/07/2007 FRAMING Partial Approval IVRS - Inspection :*
OK TO INSULATE

1. NEED GIRDER TO BEAM HANGER PAPERWORK
11/01/2007 FRAMING Partial Approval IVRS - Inspection :*
1) PENDING ALL TRADES
2) FINISH ROMEX TO FLOOR RECEPT
3) GAUGE AT ZERO
4) FIRESTOP TUB SHOE UPSTAIRS
5) ENGINEERED FIX AT CUT TRIPLE GIRDER TRUSS UPSTAIRS
10/25/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CHANGE OUT HANGER AT ROOF FROM EXT. CLIP INSPECTION
2) FINISH ROMEX TO FLOOR RECEPT
3) NEED TO SHORTEN TUB TRAP ARM
4) REPAIR SHEAR AT KITCHEN SHEAR
5) BANG PLATE AT DIVERTER STUD, OVER NOTCHED STUD 1ST FLOOR
6) BLOCK ALL MECH
7) DRILL HOLE IN SCKEWED HANGER AND NAIL AT STAIR HEADER
8) NO H20 IN SOIL LINES 2ND FLOOR