Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/25/2008 | FRAMING | Approved | IVRS - Inspection :* 1) SEE ATTACHMENT ON ENGINEERED TRUSS REPAIR |
|
01/24/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED ROB'S APPROVAL ON ENGINEERED LETTER |
|
01/07/2008 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
12/28/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
12/06/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NEED TRUSS REPAIR AT CUT TRUSS |
|
12/04/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAILS NOT CHANGED OUT |
|
12/03/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) WRONG NAILS IN (PROBLEM HANGER) |
|
11/28/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOTE: HTU26-2 INSTALLED WITH .148 SINKERS AND NAIL 3 1/2" LONG HANGER CALLS FOR 16 .162 = .64 PERCENT REDUCTION IN LOAD CAPACITY. TO RENAIL USE COMMON 16D 3 1/2" LONG |
|
11/27/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) HANGER PROBLEM NOT RESOLVED-OK WAS GIVEN TO INSULATE NOT SHEETROCK |
|
11/23/2007 | FRAMING | Cancelled | IVRS - RI canceled | |
11/07/2007 | FRAMING | Partial Approval | IVRS - Inspection :* OK TO INSULATE 1. NEED GIRDER TO BEAM HANGER PAPERWORK |
|
11/01/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PENDING ALL TRADES 2) FINISH ROMEX TO FLOOR RECEPT 3) GAUGE AT ZERO 4) FIRESTOP TUB SHOE UPSTAIRS 5) ENGINEERED FIX AT CUT TRIPLE GIRDER TRUSS UPSTAIRS |
|
10/25/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CHANGE OUT HANGER AT ROOF FROM EXT. CLIP INSPECTION 2) FINISH ROMEX TO FLOOR RECEPT 3) NEED TO SHORTEN TUB TRAP ARM 4) REPAIR SHEAR AT KITCHEN SHEAR 5) BANG PLATE AT DIVERTER STUD, OVER NOTCHED STUD 1ST FLOOR 6) BLOCK ALL MECH 7) DRILL HOLE IN SCKEWED HANGER AND NAIL AT STAIR HEADER 8) NO H20 IN SOIL LINES 2ND FLOOR |