Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/08/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 01/07/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. CALL IN AND HAVE APPROVED ALL PLUMBING INSPECTIONS THAT HAVE NOT BEEN APPROVED 2. PROVIDE CORRECT BACKFLOW & CERTIFICATIONS FOR ALL DEVICES REQUIRING PROTECTION 3. MAKE ALL FIXTURES WATER TIGHT 4. SUPPORT & SECURE ALL DEVICES PROPERLY 5. COMPLETE INSULATION ON HOT & RETURN PIPING 6. SUPPORT GAS PIPING AT WATER HEATER 7. PROVIDE SUPPORT FOR PIPING AT WATER INLET FOR DISHWASHER 8. PROVIDE LISTING FOR COPPER FITTINGS WITH BUILT IN SOLDER OR PROVIDE WROT TEES AT DISHWASHER LOCATION. |
|
| 01/03/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* MAKE ALL CONNECTIONS CONNECT ALL DRAINS MIXING VALVES REQUIRE SUPPORT |