Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07CM02355
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/08/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
01/07/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. CALL IN AND HAVE APPROVED ALL PLUMBING INSPECTIONS THAT HAVE NOT BEEN APPROVED 2. PROVIDE CORRECT BACKFLOW & CERTIFICATIONS FOR ALL DEVICES REQUIRING PROTECTION 3. MAKE ALL FIXTURES WATER TIGHT 4. SUPPORT & SECURE ALL DEVICES PROPERLY 5. COMPLETE INSULATION ON HOT & RETURN PIPING 6. SUPPORT GAS PIPING AT WATER HEATER 7. PROVIDE SUPPORT FOR PIPING AT WATER INLET FOR DISHWASHER 8. PROVIDE LISTING FOR COPPER FITTINGS WITH BUILT IN SOLDER OR PROVIDE WROT TEES AT DISHWASHER LOCATION. |
|
01/03/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* MAKE ALL CONNECTIONS CONNECT ALL DRAINS MIXING VALVES REQUIRE SUPPORT |