Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/09/2007 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 11/02/2007 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED GFCI IN BATHROOM 2) IN SUB-PANEL, NEED SEPERATE NEUTRAL GRD WIRES, INSTALL GRD BAR, BUSHING AT KNOCKOUT, SQUARE D BREAKER USED IN MURRAY PANEL 3) PLUMBING VENTING FOR SHOWER, UNCOVER 2" DRAIN TO MAIN, OR SHOWER CONNECTION TO SEWER, UNCOVER BLDG SEWER CONNECTION 4) AT NEXT INSPECT WILL CUT SMALL INSPECTION HOLE TO SPOT CHECK FOR ROMEX PROTECTION AT METAL STUDS 5) WORK DONE WITHOUT PREVIOUS INSPECTIONS OR PERMIT 6) NEED TO RAISE VENT ABOVE ROOF LINE AND SECURE PLUMBING TO WALL |