Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07CM02342
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/01/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
09/28/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. ALL CLEANOUT COVERS REQUIRE FACTORY TAPPED CLEANOUT PLUGS & MACHINE SCREWS THAT DO NOT PENETRATE INTO SANITARY VENT SYSTEM 2. HANDICAP STOOLS REQUIRE FLUSH HANDLE TO WIDE SIDE OF RESTROOM 3. CORRECTLY TERMINATE 1" CONDENSATE WITH FURRULE AND SLIP JOINT NUT AT LAV TAILPIECE |
|
09/27/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* CONTRACTOR CANCELLED |