Permit: T07CM02340

Parcel: 11502141D


Addresses:

640 E LESTER ST #01


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T07CM02340

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
06/25/2008 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
06/24/2008 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TO REMOVE ALL SIDING THAT IS NOT SHEAR, TO INSPECT CLIPS
2) SHEARWALL #3 WEST SIDE NOT NAILED PER SHEAR PLAN
3) NEED TO BE ABLE TO INSPECT ALL HOLDOWNS
4) NEED PROPER LADDER TO ACCESS ROOF
5) NEED TRUSS CALCS
6) NEED A GOOD SET OF CITY APPROVED PLANS THAT ARE EAST TO WORK WITH
03/28/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) BLDG FOOTING OK TO POUR
2) NEED PROPER CLAMP AT REBAR CONNECTION-NO ACORN ALLOWED
3) CHECK ADDRESS AT PROPERTY SIGN S/B 640 NOT 660 ?