Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/14/2008 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* 1) AT NEXT INSPECTION HAVE BEAM SIZE CHANGED ON PLAN AT OLD CARPORT FROM 4 X10 TO 5 1/8" X 7 1/2" GLU LAM 2) REMEMBER TO PUT ANCHOR BOLTS, IN TOP OF WALL AT FRONT OF AND SIDE OF WALL OLD CARPORT. ANCHOR BOLTS TO TIE TOP PLATE TO BLOCK WALL |
|
| 07/09/2008 | REINFORCED MASONRY PRE-GROUT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. YOU ARE OK EXCEPT THE FRONT WALL UNDER THE EXISTING ROOF. YOU NEED TO REMOVE ONE COURSE OF BLOCK. TO ATTAIN 8" BOND BEAM. SEE LAST INSPECTION. |
|
| 02/22/2008 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1) 1ST 4' LIFT OK |