Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM02309

Parcel: 11502482E


Addresses:

416 E LEE ST


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM02309

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
02/05/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
02/04/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
01/09/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) H.D. NEEDS TO BE NAILED PROPERLY AT STUDS
2) NEED TO INSTALL SUPPORT POST PER 13/A6 AT GARAGE
3) CST STRAP WRONG LOCATION ON NORTH EAST SHEARWALL
4) MISSING SIMPSON CONNECTION ON 6 X 6 POST AT GARAGE