Permit: T07CM02308

Parcel: 122161360


Addresses:

3832 E HAMPTON ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/18/2007 FRAMING Approved IVRS - Inspection :*
10/11/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIREPLACE NOT INSTALLED TO SPECS
2) GAS LINE TO FIREPLACE WRONG SIZE NEEDS TO BE 3/4"
3) FOLLOW APPROVED PLANS OR REVISE
4) WARNING: A REINSPECTION FEE WILL APPLY IF NOT IN COMPLIANCE AT NEXT RECALL
10/02/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE INSULATION DAMPER VENT AT FIREPLACE
2) PROVIDE SPECS FOR FIREPLACE
3) PLUMBING ROUGH NOT PER PLANS (CHECK VENTS)
4) NEED TO ADD GAS FIREPLACE WITH CALC'S TO PLANS
5) SUPPORT CONDENSATE LINE AND PROTECT WITH NAIL PLATES
6) MAINTAIN 1" SEPERATION AT B-VENT TO COMBUSTIBLES
7) GAS LINE TO WATER HEATER
8) CALCED OUT TO BE 3/4" NOT 1/2"
9) PROVIDE A COMPLETE WATER TEST ON ALL DWV
09/25/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
08/29/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
08/27/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLY WITH PREVIOUS NOTES 2, 3 & 5
08/23/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
08/20/2007 FRAMING Partial Approval IVRS - Inspection :*
1) CLIPS ON LEDGERS AND BARGE BOARDS OK